Totalstation Setup with GNSS Rover

To get startet with the measurements with the totalstation, you have to know the exact position of the station. For this, you can use the GNSS to identify exact positions of the prism reflector which you then measure with the totalstation.

Connecting the equipment

Total station (TS or TPS) can be used with a single rover or rover-base GNSS combinations. The following describes the steps required for measuring terrain and trees in the Marburg Open Forest.

  • Start the X-Pad application

ts_meas_Screenshot_2020-01-28-15-46-34.png

  • Select the required job or create a new one

ts_meas_Screenshot_2020-01-28-15-46-52.png

  • To connect the equipment press Settings

ts_meas_Screenshot_2020-01-28-15-47-19.png

  • In Settings, select GNSS and Total station

ts_meas_Screenshot_2020-01-28-15-47-30.png

  • Depending on the context, tap either Zenith35PRO Rover1 or Zenith35PRO_RoverWithBase

ts_meas_Screenshot_2020-01-28-15-47-48.png

  • Press configure and wait until the end of the process

ts_meas_Screenshot_2020-01-28-15-48-02.png

  • Tap Totalstation Zoom 70 and choose current

ts_meas_Screenshot_2020-01-28-15-49-33.png

Station Coordinates and Orientation definition

  • Go to Survey tab and tap Station setup

ts_meas_Screenshot_2020-01-28-15-49-52.png

  • Press New setup

ts_meas_Screenshot_2020-01-28-15-50-06.png

  • Select No. Station position has to be calculated

ts_meas_Screenshot_2020-01-28-15-50-14.png

  • Choose Free station

ts_meas_Screenshot_2020-01-28-15-50-20.png

  • For Free station, Instr. Height makes no sence (only if the ground point elevation will be used), thus, go Next

ts_meas_Screenshot_2020-01-28-15-50-44.png

  • Specify reference points (minimum two points are required, three recommended)

ts_meas_Screenshot_2020-01-28-15-51-32.png

  • Select the bottom-left green circle and adjust the level if necessary (do not change the level at any further step!)

ts_meas_Screenshot_2020-01-28-16-09-42.png

  • Press the Unlock button and tap Lock, the TS should be pointed to the prisma with GNSS. Go back

ts_meas_Screenshot_2020-01-28-16-10-05.png

  • In the point field select measure and press the Measure button, select the required GNSS device

ts_meas_Screenshot_2020-01-28-16-12-22.png

ts_meas_Screenshot_2020-01-28-16-12-57.png

  • Set the Antenna height (correct by default)

ts_meas_Screenshot_2020-01-28-16-13-11.png

  • Make sure that the horizontal and vertical errors are appropriate, press Measure. Change position of the prism and repeate the procedure

ts_meas_Screenshot_2020-01-28-16-13-42.png

Shooting/Measuring

  • In Survey tab, press survey points, by default measures are conducted with the prism

ts_meas_Screenshot_2020-01-28-16-19-20.png

  • Tap the top-left prism icon and chose the reflectorless mode for massive shooting, tap the laser pointer to speed up the measurement

ts_meas_Screenshot_2020-01-28-16-20-30.png

  • Use Measure and Store for massive shooting, modify the point name (use conventional prefixes and predefined codes)

ts_meas_Screenshot_2020-01-28-16-21-00.png