You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
I use OZW inside Domoticz, but since the last release (where they upgraded from 1.4xx to 1.6xx) neither of my smart plugs is showing any power values. This is an Aeotec ZW096, and a Fibaro fgwp121 (upgrade from the 111, and yes, I know there is missing .xml for this model, at least the xml is there but not references from the supplier specific file).
I do have switch status (and can change it), and also various colour related stuff on the aeon model - only locked/unlocked for the Fibaro - but ozw control panel shows nothing by way of energy/power values for either device. Where should I be looking?
Node 38 is the Fibaro switch (missing power), 32 is the Aeon smartswitch (ditto).
I use OZW inside Domoticz, but since the last release (where they upgraded from 1.4xx to 1.6xx) neither of my smart plugs is showing any power values. This is an Aeotec ZW096, and a Fibaro fgwp121 (upgrade from the 111, and yes, I know there is missing .xml for this model, at least the xml is there but not references from the supplier specific file).
I do have switch status (and can change it), and also various colour related stuff on the aeon model - only locked/unlocked for the Fibaro - but ozw control panel shows nothing by way of energy/power values for either device. Where should I be looking?
Node 38 is the Fibaro switch (missing power), 32 is the Aeon smartswitch (ditto).
Attaching startup log and .jpg of the node list
2021-05-05 17:24:44.685 Zenstick 5: OpenZWave: Value_Added: Node: 32 (0x20), CommandClass: CLOCK, Label: Day, Instance: 1, Index: 0
2021-05-05 17:24:44.685 Zenstick 5: OpenZWave: Value_Added: Node: 32 (0x20), CommandClass: CLOCK, Label: Hour, Instance: 1, Index: 1
2021-05-05 17:24:44.686 Zenstick 5: OpenZWave: Value_Added: Node: 32 (0x20), CommandClass: CLOCK, Label: Minute, Instance: 1, Index: 2
2021-05-05 17:24:44.686 Zenstick 5: OpenZWave: NodeID: 32 (0x20), Thermostat Clock: Monday 16:56
2021-05-05 17:24:44.687 Zenstick 5: General/Thermostat Clock (Thermostat Clock)
2021-05-05 17:24:44.687 Zenstick 5: OpenZWave: Value_Added: Node: 36 (0x24), CommandClass: SCENE ACTIVATION, Label: Scene, Instance: 1, Index: 0
2021-05-05 17:24:44.687 Zenstick 5: OpenZWave: Value_Added: Node: 36 (0x24), CommandClass: SCENE ACTIVATION, Label: Duration, Instance: 1, Index: 1
2021-05-05 17:24:44.687 Zenstick 5: OpenZWave: Value_Added: Node: 36 (0x24), CommandClass: SENSOR BINARY, Label: Instance 1: Sensor, Instance: 1, Index: 0
2021-05-05 17:24:44.688 Zenstick 5: OpenZWave: Value_Added: Node: 36 (0x24), CommandClass: SENSOR BINARY, Label: Instance 2: Sensor, Instance: 2, Index: 0
2021-05-05 17:24:44.688 Zenstick 5: OpenZWave: Value_Added: Node: 36 (0x24), CommandClass: SENSOR MULTILEVEL, Label: Instance 1: Air Temperature, Instance: 1, Index: 1
2021-05-05 17:24:44.688 Zenstick 5: OpenZWave: Value_Added: Node: 36 (0x24), CommandClass: SENSOR MULTILEVEL, Label: Instance 2: Air Temperature, Instance: 2, Index: 1
2021-05-05 17:24:44.688 Zenstick 5: OpenZWave: Value_Added: Node: 36 (0x24), CommandClass: SENSOR MULTILEVEL, Label: Instance 1: Unknown, Instance: 1, Index: 142
2021-05-05 17:24:44.690 Zenstick 5: OpenZWave: Value_Added: Node: 37 (0x25), CommandClass: METER, Label: Electric - kWh, Instance: 1, Index: 0
2021-05-05 17:24:44.690 Zenstick 5: OpenZWave: Value_Added: Node: 37 (0x25), CommandClass: METER, Label: Electric - W, Instance: 1, Index: 2
2021-05-05 17:24:44.690 Zenstick 5: OpenZWave: Value_Added: Node: 37 (0x25), CommandClass: METER, Label: Electric - V, Instance: 1, Index: 4
2021-05-05 17:24:44.690 Zenstick 5: OpenZWave: Value_Added: Node: 37 (0x25), CommandClass: METER, Label: Electric - A, Instance: 1, Index: 5
2021-05-05 17:24:44.690 Zenstick 5: OpenZWave: Value_Added: Node: 37 (0x25), CommandClass: METER, Label: Electric - kVar, Instance: 1, Index: 8
2021-05-05 17:24:44.690 Zenstick 5: OpenZWave: Value_Added: Node: 37 (0x25), CommandClass: METER, Label: Electric - kVarh, Instance: 1, Index: 9
2021-05-05 17:24:44.690 Zenstick 5: OpenZWave: Value_Added: Node: 37 (0x25), CommandClass: METER, Label: Exporting, Instance: 1, Index: 256
2021-05-05 17:24:44.693 Zenstick 5: OpenZWave: Value_Added: Node: 38 (0x26), CommandClass: SWITCH BINARY, Label: Switch, Instance: 1, Index: 0
2021-05-05 17:24:44.317 Status: Zenstick 5: OpenZWave: using config in: /home/pi/domoticz/Config/
2021-05-05 17:24:44.324 Status: Zenstick 5: OpenZWave: Starting...
2021-05-05 17:24:44.324 Status: Zenstick 5: OpenZWave: Version: 1.6-1911-gc6a420ef
2021-05-05 17:24:44.374 Status: Zenstick 5: OpenZWave: A DNS Error Occurred
2021-05-05 17:24:44.375 Status: Zenstick 5: OpenZWave: ManufacturerSpecificDB Ready
2021-05-05 17:24:44.660 Status: Zenstick 5: OpenZWave: Driver Ready
2021-05-05 17:24:44.676 Status: Zenstick 5: OpenZWave: Value_Added: Warning: OpenZWave returned ValueLabel "Unknown" on Node: 25 (0x19), CommandClass: SENSOR MULTILEVEL, Label: Unknown, Instance: 1, Index: 91
2021-05-05 17:24:44.676 Status: Zenstick 5: OpenZWave: Value_Added: Unhandled Label: Unknown, Unit: , Node: 25 (0x19), CommandClass: SENSOR MULTILEVEL, Label: Unknown, Instance: 1, Index: 91
2021-05-05 17:24:44.684 Status: Zenstick 5: SendSwitchIfNotExists: Device '32.instance.1.index.0.commandClasses.38' (Level) with DeviceID '00002001' matches '32.instance.1.index.0.commandClasses.37' (Switch). Domoticz will use the Dimmer (and hide the Switch).
2021-05-05 17:24:44.688 Status: Zenstick 5: OpenZWave: Value_Added: Unhandled Label: Instance 1: Unknown, Unit: , Node: 36 (0x24), CommandClass: SENSOR MULTILEVEL, Label: Instance 1: Unknown, Instance: 1, Index: 142
2021-05-05 17:24:45.447 Zenstick 5: Temp + Humidity (Greenhouse TempHum)
2021-05-05 17:24:47.760 Status: Zenstick 5: OpenZWave: Received timeout notification from HomeID: 3619703272, NodeID: 18 (0x12)
2021-05-05 17:24:48.761 Status: Zenstick 5: OpenZWave: Received timeout notification from HomeID: 3619703272, NodeID: 19 (0x13)
2021-05-05 17:24:49.994 Zenstick 5: Temp + Humidity (Greenhouse TempHum)
2021-05-05 17:24:51.305 Zenstick 5: Temp + Humidity (Greenhouse TempHum)
2021-05-05 17:24:51.803 Zenstick 5: Temp + Humidity (Greenhouse TempHum)
2021-05-05 17:24:53.125 Zenstick 5: Temp + Humidity (Conservatory TempHum)
2021-05-05 17:24:53.359 Zenstick 5: Temp + Humidity (Greenhouse TempHum)
2021-05-05 17:24:53.549 Zenstick 5: Temp + Humidity (Greenhouse TempHum)
2021-05-05 17:24:54.569 Zenstick 5: Temp + Humidity (Conservatory TempHum)
2021-05-05 17:24:54.937 RFXCom: Temp (Temp #1)
2021-05-05 17:24:55.129 RFXCom: Temp (Temp #2)
2021-05-05 17:24:55.450 Zenstick 5: Temp + Humidity (Greenhouse TempHum)
2021-05-05 17:24:57.261 Zenstick 5: Lux (Greenhouse Lux)
2021-05-05 17:24:57.359 Zenstick 5: Temp + Humidity (Conservatory TempHum)
2021-05-05 17:24:57.653 Zenstick 5: Lux (Greenhouse Lux)
2021-05-05 17:24:57.763 Status: Zenstick 5: OpenZWave: Received timeout notification from HomeID: 3619703272, NodeID: 25 (0x19)
2021-05-05 17:25:00.017 Zenstick 5: Temp + Humidity (Conservatory TempHum)
2021-05-05 17:25:03.036 Status: Zenstick 5: OpenZWave: Received timeout notification from HomeID: 3619703272, NodeID: 28 (0x1c)
2021-05-05 17:25:06.038 Status: Zenstick 5: OpenZWave: Received timeout notification from HomeID: 3619703272, NodeID: 29 (0x1d)
2021-05-05 17:25:07.485 Zenstick 5: UV (UV)
2021-05-05 17:25:10.729 Status: Zenstick 5: OpenZWave: Received timeout notification from HomeID: 3619703272, NodeID: 38 (0x26)
2021-05-05 17:25:11.731 Status: Zenstick 5: OpenZWave: Received timeout notification from HomeID: 3619703272, NodeID: 4 (0x04)
2021-05-05 17:25:12.819 Status: Zenstick 5: OpenZWave: Received timeout notification from HomeID: 3619703272, NodeID: 17 (0x11)
2021-05-05 17:25:14.506 Zenstick 5: Temp + Humidity (Greenhouse TempHum)
2021-05-05 17:25:14.907 Zenstick 5: Temp + Humidity (Greenhouse TempHum)
2021-05-05 17:25:16.570 Zenstick 5: Temp + Humidity (Greenhouse TempHum)
2021-05-05 17:25:16.818 Zenstick 5: Lux (Conservatory Lux)
2021-05-05 17:25:16.923 Zenstick 5: Temp + Humidity (Greenhouse TempHum)
2021-05-05 17:25:19.020 Zenstick 5: Lux (Conservatory Lux)
2021-05-05 17:25:19.492 Zenstick 5: Temp + Humidity (Greenhouse TempHum)
2021-05-05 17:25:20.292 Zenstick 5: Lux (Conservatory Lux)
2021-05-05 17:25:20.329 RFXCom: Temp + Humidity (Loft)
2021-05-05 17:25:21.556 Zenstick 5: Lux (Greenhouse Lux)
2021-05-05 17:25:22.104 RFXCom: Temp + Humidity (Living Room Temp / Humid)
2021-05-05 17:25:24.281 RFXCom: Temp (Temp #1)
2021-05-05 17:25:24.476 RFXCom: Temp (Temp #2)
2021-05-05 17:25:24.838 Status: Zenstick 5: OpenZWave: Received timeout notification from HomeID: 3619703272, NodeID: 25 (0x19)
2021-05-05 17:25:27.917 Status: Zenstick 5: OpenZWave: Received timeout notification from HomeID: 3619703272, NodeID: 32 (0x20)
2021-05-05 17:25:30.814 Zenstick 5: Temp + Humidity (Conservatory TempHum)
2021-05-05 17:25:30.919 Status: Zenstick 5: OpenZWave: Received timeout notification from HomeID: 3619703272, NodeID: 36 (0x24)
2021-05-05 17:25:33.973 Status: Zenstick 5: OpenZWave: Received timeout notification from HomeID: 3619703272, NodeID: 38 (0x26)
2021-05-05 17:25:34.975 Status: Zenstick 5: OpenZWave: Received timeout notification from HomeID: 3619703272, NodeID: 4 (0x04)
2021-05-05 17:25:35.978 Status: Zenstick 5: OpenZWave: Received timeout notification from HomeID: 3619703272, NodeID: 18 (0x12)
2021-05-05 17:25:36.034 Zenstick 5: UV (UV)
2021-05-05 17:25:36.689 Zenstick 5: UV (UV)
2021-05-05 17:25:37.003 Zenstick 5: General/kWh (House Load (Aeotec))
2021-05-05 17:25:41.647 Zenstick 5: UV (UV)
2021-05-05 17:25:44.292 Zenstick 5: Temp + Humidity (Greenhouse TempHum)
2021-05-05 17:25:47.362 Status: Zenstick 5: OpenZWave: Received timeout notification from HomeID: 3619703272, NodeID: 27 (0x1b)
2021-05-05 17:25:48.363 Status: Zenstick 5: OpenZWave: Received timeout notification from HomeID: 3619703272, NodeID: 38 (0x26)
2021-05-05 17:25:49.112 Zenstick 5: Temp + Humidity (Greenhouse TempHum)
2021-05-05 17:25:49.202 Zenstick 5: Temp + Humidity (Greenhouse TempHum)
2021-05-05 17:25:53.191 Zenstick 5: Temp + Humidity (Greenhouse TempHum)
2021-05-05 17:25:53.420 Zenstick 5: Lux (Greenhouse Lux)
2021-05-05 17:25:53.599 Zenstick 5: UV (UV)
2021-05-05 17:25:53.613 RFXCom: Temp (Temp #1)
2021-05-05 17:25:53.802 RFXCom: Temp (Temp #2)
2021-05-05 17:25:56.702 Zenstick 5: Temp + Humidity (Conservatory TempHum)
2021-05-05 17:25:58.001 Zenstick 5: Temp + Humidity (Conservatory TempHum)
2021-05-05 17:25:58.227 Zenstick 5: Temp (Garage Roof Slates)
2021-05-05 17:25:58.408 Zenstick 5: Temp (Garage Interior)
2021-05-05 17:26:02.717 Status: Zenstick 5: OpenZWave: Received timeout notification from HomeID: 3619703272, NodeID: 18 (0x12)
2021-05-05 17:26:03.725 Status: Zenstick 5: OpenZWave: Received timeout notification from HomeID: 3619703272, NodeID: 18 (0x12)
2021-05-05 17:26:04.096 Zenstick 5: UV (UV)
2021-05-05 17:26:05.105 RFXCom: Temp + Humidity (Living Room Temp / Humid)
2021-05-05 17:26:05.615 RFXCom: Temp + Humidity (Loft)
2021-05-05 17:26:09.342 Zenstick 5: Temp + Humidity (Conservatory TempHum)
2021-05-05 17:26:10.081 Zenstick 5: Temp + Humidity (Conservatory TempHum)
2021-05-05 17:26:13.371 Zenstick 5: Lux (Conservatory Lux)
2021-05-05 17:26:13.080 Status: Zenstick 5: OpenZWave: Received timeout notification from HomeID: 3619703272, NodeID: 25 (0x19)
2021-05-05 17:26:16.190 Zenstick 5: Temp + Humidity (Greenhouse TempHum)
2021-05-05 17:26:16.365 Status: Zenstick 5: OpenZWave: Received timeout notification from HomeID: 3619703272, NodeID: 25 (0x19)
2021-05-05 17:26:17.905 Zenstick 5: Temp + Humidity (Conservatory TempHum)
2021-05-05 17:26:19.367 Status: Zenstick 5: OpenZWave: Received timeout notification from HomeID: 3619703272, NodeID: 25 (0x19)
2021-05-05 17:26:20.369 Status: Zenstick 5: OpenZWave: Received timeout notification from HomeID: 3619703272, NodeID: 25 (0x19)
2021-05-05 17:26:22.954 RFXCom: Temp (Temp #1)
2021-05-05 17:26:23.151 RFXCom: Temp (Temp #2)
2021-05-05 17:26:26.522 Zenstick 5: Temp + Humidity (Greenhouse TempHum)
2021-05-05 17:26:26.640 Zenstick 5: Lux (Greenhouse Lux)
2021-05-05 17:26:26.653 Zenstick 5: Temp + Humidity (Greenhouse TempHum)
2021-05-05 17:26:29.182 Zenstick 5: UV (UV)
2021-05-05 17:26:33.579 Status: Zenstick 5: OpenZWave: Received timeout notification from HomeID: 3619703272, NodeID: 37 (0x25)
2021-05-05 17:26:34.752 Zenstick 5: UV (UV)
2021-05-05 17:26:36.639 Zenstick 5: Usage (New Power)
2021-05-05 17:26:36.649 Zenstick 5: General/kWh (House Load (Aeotec))
2021-05-05 17:26:36.661 Zenstick 5: General/kWh (kVar Meter)
2021-05-05 17:26:36.670 Zenstick 5: General/kWh (kVarh Meter)
2021-05-05 17:26:36.698 Zenstick 5: General/Voltage (Voltage)
2021-05-05 17:26:36.747 Zenstick 5: Current (Unknown)
2021-05-05 17:26:36.970 Zenstick 5: Temp + Humidity (Conservatory TempHum)
2021-05-05 17:26:36.588 Status: Zenstick 5: OpenZWave: Received timeout notification from HomeID: 3619703272, NodeID: 37 (0x25)
2021-05-05 17:26:37.478 Zenstick 5: Lux (Conservatory Lux)
2021-05-05 17:26:38.065 Zenstick 5: UV (UV)
2021-05-05 17:26:39.742 Status: Zenstick 5: OpenZWave: Received timeout notification from HomeID: 3619703272, NodeID: 37 (0x25)
2021-05-05 17:26:40.790 Zenstick 5: Temp (Garage Roof Slates)
2021-05-05 17:26:40.847 Zenstick 5: Temp (Garage Interior)
2021-05-05 17:26:42.746 Status: Zenstick 5: OpenZWave: Received timeout notification from HomeID: 3619703272, NodeID: 37 (0x25)
2021-05-05 17:26:45.753 Status: Zenstick 5: OpenZWave: Received timeout notification from HomeID: 3619703272, NodeID: 38 (0x26)
2021-05-05 17:26:46.755 Status: Zenstick 5: OpenZWave: Received timeout notification from HomeID: 3619703272, NodeID: 38 (0x26)
2021-05-05 17:26:47.757 Status: Zenstick 5: OpenZWave: Received timeout notification from HomeID: 3619703272, NodeID: 38 (0x26)
2021-05-05 17:26:48.103 RFXCom: Temp + Humidity (Living Room Temp / Humid)
2021-05-05 17:26:48.577 Zenstick 5: Temp + Humidity (Greenhouse TempHum)
2021-05-05 17:26:50.325 RFXCom: Temp + Humidity (Loft)
2021-05-05 17:26:52.278 RFXCom: Temp (Temp #1)
2021-05-05 17:26:52.487 RFXCom: Temp (Temp #2)
2021-05-05 17:26:53.090 Zenstick 5: Temp + Humidity (Greenhouse TempHum)
2021-05-05 17:26:55.760 Status: Zenstick 5: OpenZWave: Received timeout notification from HomeID: 3619703272, NodeID: 38 (0x26)
2021-05-05 17:26:57.284 Zenstick 5: Temp + Humidity (Greenhouse TempHum)
2021-05-05 17:26:57.106 Status: Zenstick 5: OpenZWave: Received timeout notification from HomeID: 3619703272, NodeID: 32 (0x20)
2021-05-05 17:26:59.167 Zenstick 5: UV (UV)
2021-05-05 17:27:03.776 Zenstick 5: Temp + Humidity (Conservatory TempHum)
2021-05-05 17:27:05.533 Zenstick 5: Temp + Humidity (Conservatory TempHum)
2021-05-05 17:27:07.901 Zenstick 5: Temp + Humidity (Conservatory TempHum)
2021-05-05 17:27:09.443 Zenstick 5: Temp + Humidity (Conservatory TempHum)
2021-05-05 17:27:10.657 Zenstick 5: Temp + Humidity (Conservatory TempHum)
2021-05-05 17:27:13.019 Zenstick 5: Lux (Conservatory Lux)
2021-05-05 17:27:13.577 Zenstick 5: UV (UV)
2021-05-05 17:27:14.264 Zenstick 5: Temp + Humidity (Greenhouse TempHum)
2021-05-05 17:27:17.059 Zenstick 5: Color Switch (Unknown)
2021-05-05 17:27:17.256 Zenstick 5: OpenZWave: NodeID: 32 (0x20), Thermostat Clock: Monday 20:02
2021-05-05 17:27:17.258 Zenstick 5: General/Thermostat Clock (Thermostat Clock)
2021-05-05 17:27:17.550 Status: Zenstick 5: OpenZWave: All Nodes queried