Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathplc_test.py
141 lines (111 loc) · 4.48 KB
/
plc_test.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
from pymodbus.client import ModbusTcpClient
from pymodbus.exceptions import ModbusIOException
import json
# PLC IP address
PLC_IP = "192.168.20.50"
# Modbus port
MODBUS_PORT = 502
def load_config(filename):
with open(filename, "r") as file:
config = json.load(file)
return config
def discover_coils(client, config):
all_coil_addresses = set(config["output_module"]["coil_addresses"].values())
all_coil_addresses.update(config["input_module"]["coil_addresses"].values())
existing_coil_addresses = set()
try:
for address in all_coil_addresses:
result = client.read_coils(address, 1)
if result.bits:
existing_coil_addresses.add(address)
except ModbusIOException:
pass
missing_coil_addresses = all_coil_addresses - existing_coil_addresses
return existing_coil_addresses, missing_coil_addresses
def discover_coils_registers(client):
try:
# Read coils and registers
coils = client.read_coils(0, 16) # Read first 16 coils
registers = client.read_holding_registers(0, 16) # Read first 16 registers
return coils.bits, registers.registers
except ModbusIOException:
print("Failed to read coils and registers.")
return None, None
def read_coil(client, address):
try:
result = client.read_coils(address,1)
if isinstance(result,ModbusIOException):
raise result
return result.bits[0]
except ModbusIOException:
print("Failed to read coil at address", address)
return None
def write_coil(client, address, value):
try:
client.write_coil(address, value)
print("Coil at address", address, "set to", value)
except ModbusIOException:
print("Failed to write coil at address", address)
def read_register(client, address):
try:
result = client.read_holding_registers(address, 1)
return result.registers[0]
except ModbusIOException:
print("Failed to read register at address", address)
return None
def write_register(client, address, value):
try:
client.write_register(address, value)
print("Register at address", address, "set to", value)
except ModbusIOException:
print("Failed to write register at address", address)
def read_output_status(client, config, output_name):
output_address = config["output_module"]["coil_addresses"].get(output_name)
if output_address is not None:
result = client.read_coils(output_address, 1)
if result.bits:
return result.bits[0]
return None
def run_example_1():
client = ModbusTcpClient(PLC_IP, port=MODBUS_PORT)
if client.connect():
coils, registers = discover_coils_registers(client)
if coils is not None and registers is not None:
print("Discovered Coils:", coils)
print("Discovered Registers:", registers)
# Example usage
coil_address = 0
register_address = 0
read_value = read_coil(client, coil_address)
if read_value is not None:
print("Read Coil Value:", read_value)
write_coil(client, coil_address, True)
read_value = read_register(client, register_address)
if read_value is not None:
print("Read Register Value:", read_value)
write_register(client, register_address, 123)
client.close()
else:
print("Failed to connect to the PLC.")
def run_example_2():
config = load_config("config.json")
client = ModbusTcpClient(PLC_IP, port=MODBUS_PORT)
if client.connect():
# Replace 'output_1' with the name of the desired output
output_name = 'output_1'
led_status = read_output_status(client, config, output_name)
if led_status is not None:
print("LED Status:", led_status)
# Toggle LED based on status
if led_status:
print("Turning LED OFF")
write_coil(client, config["output_module"]["coil_addresses"][output_name], False)
else:
print("Turning LED ON")
write_coil(client, config["output_module"]["coil_addresses"][output_name], True)
client.close()
else:
print("Failed to connect to the PLC.")
if __name__ == "__main__":
# run_example_1()
run_example_2()