Notifications
You must be signed in to change notification settings - Fork 0
/
Copy path04_thermal_transient_blocks.py
176 lines (143 loc) · 8.03 KB
/
04_thermal_transient_blocks.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
"""
Script for running a thermal transient block
Author: Ramiro Mena-Andrade (CERN-CIEMAT)
Data: 2022/05/10
Comments:
- The script uses the Fluka plug-in for loading the energy deposition
- The location of the Fluka files (.lis) needs to be modified manually (if different files are applied)
- For comparison between cladding candidates a constant h=1 W/m2K is used (option=0)
Manual operations:
- The Fluka plugin does not allow to automatize two actions: application of the load and time
"""
#%%
import sys
import os
sys.path.append('C://Program Files//Ansys Inc//v202//Addins//')
def Temperature_FilmCoefficient_values(T,k,L):
T_list = []
h_list = []
for i in range(len(T)):
T_list.append(Quantity(str(T[i])+'[s]'))
h_list.append(Quantity(str(k_air[i]/L) + '[W m^-1 m^-1 C^-1]'))
return T_list, h_list
#Type of simulation
analyses_list = DataModel.AnalysisList #select all the available analyses
thermal = []
structural=[]
#Loop to classify thermal and structural analyses
for i in range(len(analyses_list)):
analysis_i = analyses_list[i].PhysicsType
if str(analysis_i) == 'Thermal':
thermal.append(str(i))
else:
structural.append(str(i))
index = int(thermal[-1]) #choose always the last index
print('Transient thermal index', index)
#analysis_i = DataModel.GetObjectsByType(DataModelObjectCategory.Analysis)#DataModel.GetObjectsByName("Transient Thermal")
#index = len(analysis_i)-2
decay_heat = analyses_list[index]#Model.Analyses[1]
option = 0 #0 for htc=1, 1 for htc=f(T)
fluka_index = int((index/2-1)) #a factor of 0.5 is included to take into account the presence of the steady state structural case
#fluka_files_wd = r'F://Simulations//BDF//LOCA//Accidental_scenario_natural_convection//Natural_Convection_LIS//'
#fluka_files_wd = r'G:/Departments/SY/Groups/STI/TCD/0050-Global_Projects/BDF Target Complex/BDF Target simulations/Solid target/FLUKA/lis_Nb_toRamiro/'
#fluka_files_wd = r'G:/Departments/SY/Groups/STI/TCD/0050-Global_Projects/BDF Target Complex/BDF Target simulations/Solid target/FLUKA/lis_Ta_toRamiro/lis_Ta_toRamiro/'
#fluka_files_wd = r'G:/Departments/SY/Groups/STI/TCD/0050-Global_Projects/BDF Target Complex/BDF Target simulations/Solid target/FLUKA/lis_NbZr_toRamiro/'
fluka_files_wd = r'G:/Departments/SY/Groups/STI/TCD/0050-Global_Projects/BDF Target Complex/BDF Target simulations/Solid target/FLUKA/lis_NbHfTi_toRamiro/'
fluka_case = ['10ms','30ms','100ms','300ms','1s','10s','60s','10m','30m','1h','2h','6h','1d','2d','4d','1w','2w','3w','1mo','2mo','3mo','1y','2y']
fluka_time = [10e-3, 30e-3, 100e-3, 300e-3, 1, 10, 60, 10*60, 30*60, 60**2, 2*60**2, 6*60**2, 24*60**2, 2*24*60**2, 4*24*60**2, 7*24*60**2, 14*24*60**2, 21*24*60**2, 31*24*60**2, 61*24*60**2,92*24*60**2, 365*24*60**2, 2*365*24*60**2]
#Create a list with the available fluka number case ID (see readmeFile)
fluka_number_case=[]
for i in range(39,45):
fluka_number_case.append(str(i))
for i in range(22,39):
fluka_number_case.append(str(i))
file_name='EnDep_NbHfTi_usrbin_'+ fluka_number_case[fluka_index]
file_ext = '.bnn.lis'
file_to_load = fluka_files_wd + file_name + file_ext
#Scrip to generate the decay heat blocks
#Air data taken from Icropera 2007
T_air = [26.85, 76.85, 126.85, 176.85, 226.85, 276.85, 326.85, 376.85, 426.85, 476.85, 526.85, 576.85, 626.85, 676.85, 726.85, 826.85, 926.85, 1026.85, 1126.85, 1226.85, 1326.85, 1426.85, 1526.85, 1626.85, 1726.85, 1826.85, 1926.85, 2026.85, 2126.85, 2226.85, 2726.85]
k_air = [0.0263,0.03,0.0338,0.0373,0.0407,0.0439,0.0469,0.0497,0.0524,0.0549,0.0573,0.0596,0.062,0.0643,0.0667,0.0715,0.0763,0.082,0.091,0.1,0.106,0.113,0.12,0.128,0.137,0.147,0.16,0.175,0.196,0.222,0.486]
L = 5e-3 #BDF channel
#Beam properties for decay heat
ppp =1 #Protons per pulse (Intensity)
pulseTime=1 #Seconds
tableName = r'load_tab'
#************************
#Thermal loads
#************************
#Define Analysis Settings time
if fluka_index == 0:
decay_heat.AnalysisSettings.StepEndTime = Quantity(fluka_time[fluka_index], "sec")
else:
decay_heat.AnalysisSettings.StepEndTime = Quantity(fluka_time[fluka_index]-fluka_time[fluka_index-1], "sec")
#Convection Load during decay heat
T_list, h_list = Temperature_FilmCoefficient_values(T_air,k_air,L) #Define the temperature and film coefficient values with a function
named_selection = DataModel.GetObjectsByName("Convection_vertical_faces") #Select the vertical faces
convection_1 = decay_heat.AddConvection() #Add convection load
convection_1.Location = named_selection[0] #Assign the selected geometry
#Select the constant or variable h value
if option == 0:
convection_1.FilmCoefficient.Output.SetDiscreteValue(0, Quantity(1, "W m^-1 m^-1 C^-1"))
else:
convection_1.FilmCoefficient.Inputs[0].DiscreteValues = T_list #Populate the table with T_list
convection_1.IndependentVariable = LoadVariableVariationType.Temperature #Define temperature as the independent variable
convection_1.FilmCoefficient.Output.DiscreteValues = h_list #Populate the table with h_list
convection_1.AmbientTemperature.Output.SetDiscreteValue(0, Quantity(26.85, "C")) #Set the ambient temperature
#Load Table FlukaV1_Beta
user_load_1= decay_heat.CreateLoadObject('CustomObj1',"FlukaV1_Beta") #Create the table
user_load_1.Properties['TbData/Filedir'].Value = file_to_load #File to load (defined on top)
user_load_1.Properties['TbData/TableName'].Value = tableName #Given name to the load
user_load_1.Properties['TbData/ApplyTable'].Value = 'applied' # Load Table
user_load_1.Properties['Inputs/ARG1'].Value = ppp #Intesity
user_load_1.Properties['Inputs/ARG2'].Value = pulseTime #Pulse Time
temp_prop = user_load_1.Properties['Options/target']
temp_prop.Value = temp_prop.Options[1] #Applied on Elements
temp_prop = user_load_1.Properties['Options/target/targetdetail']
temp_prop.Value = temp_prop.Options[1]#Average on ElementCenter
temp_prop = user_load_1.Properties['TbData/SYC']#Coordinate system
temp_prop.Value = temp_prop.Options[1]
temp_prop = user_load_1.Properties['Definition/TypeAnalysis']#WB
temp_prop.Value = temp_prop.Options[0]
temp_prop = user_load_1.Properties['GeometrySelection/Geometry/DefineBy']
temp_prop.Value = temp_prop.Options[1]
#temp_prop = user_load_1.Properties['GeometrySelection/Geometry/DefineBy/NamedSelection'] #NOT WORKING to test
#temp_prop.Value = temp_prop.Options[13]
temp_prop = user_load_1.Properties['Outputs/Output1']#Check Ansys ON
temp_prop.Value = temp_prop.Options[0]
temp_prop = user_load_1.Properties['Outputs/Output2']#Check Fluka file ON
temp_prop.Value = temp_prop.Options[0]
# named_selection = DataModel.GetObjectsByName('all')
# temperature_result_1 = decay_heat.Solution.AddTemperature()
# temperature_result_1.ScopingMethod = GeometryDefineByType.Geometry
# temperature_result_1.Location= named_selection[0]
# #endregion
named_selections = ['all','Cladding_ns','TZM_ns','W_ns']
#Create the Temperature output solution
for i in range(len(named_selections)):
named_selection = DataModel.GetObjectsByName(named_selections[i])
temperature_result_i = decay_heat.Solution.AddTemperature()
temperature_result_i.ScopingMethod = GeometryDefineByType.Geometry
temperature_result_i.Location= named_selection[0]
if i == 0:
temperature_result_i = decay_heat.Solution.AddTotalHeatFlux()
temperature_result_i.ScopingMethod = GeometryDefineByType.Geometry
temperature_result_i.Location= named_selection[0]
#region Set object property
#named_selection = DataModel.GetObjectsByName("Path 1")
#path_1 = named_selection[0]
#temperature_result_1 = Model.Analyses[2].Solution.AddTemperature()
#temperature_result_1.ScopingMethod = GeometryDefineByType.Path
#temperature_result_1.Surface = named_selection[0]
#endregion
#region Set object property
#named_selection = DataModel.GetObjectsByName("Path 2")
#path_2 = named_selection[0]
#temperature_result_2 = Model.Analyses[2].Solution.AddTemperature()
#temperature_result_2.ScopingMethod = GeometryDefineByType.Path
#temperature_result_2.Surface = named_selection[0]
#endregion
#***********************
#Run Analysis
#***********************
#Model.Analyses[2].Solve()