Skip to content

Library API to interface with the Hayward Omnilogic pool control system.

License

Notifications You must be signed in to change notification settings

hoagea/omnilogic-api

 
 

Repository files navigation

Hayward OmniLogic Integration

Integration library for Hayward Omnilogic pool controllers to allow easy integration through their API to your home automation system.

Usage

Getting it

To download OmniLogic, either fork this github repo or simply use PyPi via pip.

$ pip install omnilogic

Using it

OmniLogic provides just the core actions, you will need to code your own specific use of the returned data.

from omnilogic import OmniLogic

A simple example to return the status of your pool equipment is:

api_client = OmniLogic(username, password)

telemetry_data = await api_client.get_telemetry_data()

Functions

get_msp_config_file()

** DEPRECATED - ALL CONFIG DATA NOW RETURNED WITH THE TELEMETRY **

Returns the full configuration of the registered Omnilogic System in JSON format with all systems on your account returned in a list and all bodies-of-water captured in a list (BOWS). Additional components like lights and relays are also forced into a list to make them easier to parse. You will need to retain the MspSystemID for each pool system in order to be able to call any of the equipment change methods. Left available to allow retrieval of new configurations for addition to the get_telemetry_data method as development continues.

get_telemetry_data(APIClient)

Returns the status of all of the equipment in the Omnilogic System in JSON format (ie. pump speeds, water temperature, heat setting, etc). This data also is returned as a list with components like lights and relays grouped into lists for easy parsing. Includes key config data such as SystemIds, equipment names, equipment parameters (max/min speed etc) and alarms for common pool components.

get_alarm_list(APIClient)

Returns a list of all alarms on the pool equipment in JSON format. If there are no alarms returns JSON {'BowID', 'False'}. Also returned as a list for all pool systems on your Omnilogic account. Note that alarm information is also returned in the get_telemetry_data method so unless you need just the full list of alarms this should not be needed.

set_heater_onoff(APIClient, MSPSystemID, PoolID, HeaterID, HeaterEnable)

Turns the heater on or off (toggle). Pass the MspSystemID, PoolID and HeaterID as int and boolean True (turn on) or False (turn off) to set the heater state.

set_heater_temperature(APIClient, MspSystemID, PoolID, HeaterID, Temperature)

Sets the heater set-point to a specified temperature. Pass the MspSystemId, PoolID, HeaterID, and desired Temperature as int to set the heater target temperature.

set_pump_speed(APIClient, MspSystemID, PoolID, PumpID, Speed)

Sets the pump speed or turns the pump on or off. Pass the MspSystemID, PoolID and HeaterID as int. Pass the Speed according to the following table.

Pump Type ON OFF
Single Speed 100 0
Variable Speed 18-100 0

set_relay_valve(APIClient, MspSystemID, PoolID, EquipmentID, OnOff)

Sets a relay or valve to On/Off (Open/Close). Pass the MspSystemID, PoolID and EquipmentID of the valve or relay as int. Pass OnOff value as int according to the following table. Also used to turn on/off lights attached to a relay without changing the lightshow.

Equipment Type Value=1 Value=0
Relay ON OFF
Valve OPEN CLOSED

set_spillover_speed(APIClient, MspSystemID, PoolID, Speed)

Sets the spillover speed for a pool that supports Spillover. Pass the MspSystemID, PoolID and desired spillover Speed as int.

set_superchlorination(APIClient, MspSystemID, PoolID, ChlorID, IsOn)

Sets the SuperChlorination function on or off. Pass the MspSystemID, PoolID and the ChlorID (Equipment ID of the Chlorinator) as int. Pass IsOn as int with 1 to turn on SuperChlorination and 0 to turn off SuperChlorination.

set_lightshow(APIClient, MspSystemID, PoolID, LightID, ShowID)

Turns on and sets the desired lightshow for V1 (non-brightness/speed controlled) lights. Pass the MspSystemID, PoolID and LightID as int. Select the desired show based on the table below:

ShowID Color/Show
0 Show-Voodoo Lounge
1 Fixed-Deep Blue Sea
2 Fixed-Royal Blue
3 Fixed-Afternoon Skies
4 Fixed-Aqua Green
5 Fixed-Emerald
6 Fixed-Cloud White
7 Fixed-Warm Red
8 Fixed-Flamingo
9 Fixed-Vivid Violet
10 Fixed-Sangria
11 Show-Twilight
12 Show-Tranquility
13 Show-Gemstone
14 Show-USA
15 Show-Mardi Gras
16 Show-Cool Cabaret
17 YELLOW
18 ORANGE
19 GOLD
20 MINT
21 TEAL
22 BURNT_ORANGE
23 PURE_WHITE
24 CRISP_WHITE
25 WARM_WHITE
26 BRIGHT_YELLOW

Note that show 17-26 may not be supported by all ColorLogic Light Systems.

set_lightshowv2(APIClient, MspSystemID, PoolID, LightID, ShowID, Speed, Brightness)

Turns on and sets the desired lightshow for V2 light systems. Pass the MspSystemID, PoolID and LightID as int. Use the table from above for the desired show as int. Send brightness and speed as Int.

About

Library API to interface with the Hayward Omnilogic pool control system.

Resources

License

Stars

Watchers

Forks

Releases

No releases published

Packages

No packages published

Languages

  • Python 100.0%