In some tests, such as SCT and FGT, two ranges of values have to be defined around each observation. The ranges of admissible and valid values (see ...).
- Range of admissible values is observed value ± 20 °C
- Range of valid values is observed value ± 1 °C
- General constraints
- lower value have to be greater or equal to 0 mm
- Range of admissible values has:
- lower value is the minimum value between (observed value - 10 mm) or (observed value - 0.5 * observed value)
- higher value is the maximum value between (observed value + 10 mm) or (observed value + 0.5 * observed value)
- Range of valid values has:
- lower value is the minimum value between (observed value - 1 mm) or (observed value - 0.1 * observed value)
- higher value is the maximum value between (observed value + 1 mm) or (observed value + 0.1 * observed value)